The maximum length of the user-defined attribute name is 20 characters. The user-defined attribute that you add here must also be included in the objects.
Ensure that the attribute name is unique. Enter the original name of the user-defined attribute, not the translation. The possible formats are string, integer or double. Tekla Structures displays any missing profiles or materials on the Missing Profiles and Missing Materials tabs in the Missing Mapping dialog box. The mapping of profiles works for IFC data that has a profile name but does not include enough information for conversion. You can change your mappings later if needed.
The maps are used in conversion only if the profiles are not found from Tekla Structures catalogs. Profile conversion follows a certain logic. You can also open and modify the catalog files in a text editor. To do this, click the Catalog button. When you are done, reopen the IFC object conversion settings to take the new settings in use.
You can convert all imported IFC objects at one go using the current object conversion settings. You need to have at least two or more revisions of the same model.
To show only changes in the property details list, select the Show only changes check box, and then click a row in the changes list. Note that in the property details list, if you by accident remove one of the columns, you can bring it back by right-clicking the column title and selecting the column from the context menu. You can then drag the column to the desired location. Object conversion change management provides change detection and change management on object level.
Conversion change management is needed in the initial data change management to reduce the challenges in construction projects.
Objects are not converted automatically but you need to convert the objects using the conversion changes list. The current conversion status is displayed in the changes list and conversion management is activated. The status is based on reference model object physical changes and IFC conversion settings. The properties of a reference object are listed in the property details list that appears separately for each object when you click an object in the changes list.
Use the Select objects in the model , Get selected objects from model , and Zoom to selected check boxes to review the model and the changes and details lists. The reference object status and conversion status logic and colors:. B-reps are shown as Surface geometry , parametric profiles as Parametric and arbitrary shapes as Arbitrary. Assembly is also Arbitrary , and so are the reference objects that are selected with the Select objects in assemblies or Select objects in components selection switches.
If a previously converted reference object has changed in a newer reference model revision, you can compare the older and newer revisions of the reference model and update the conversion. You may need to select the converted objects to check the properties of the native Tekla Structures objects, for example.
The status of the converted object is reported in the changes list in the Class column. Sometimes the input data in the IFC model is not adequate to successfully create the converted object. The following table explains what the class values mean. Parametric profile with a name. There is enough information in the IFC model to convert the object successfully. Parametric profile without a name. Tekla Structures determines the name of the object based on the objects profile. Arbitrary profile with a name.
The profile of the converted object may be incorrectly rotated because there is no parametrized profile data in the IFC model. Arbitrary profile without a name. B-rep piece with a name. The profile may be an extrema box due to the lack of profile data in the IFC model. B-rep piece without a name. B-rep piece. The object is converted using the Convert B-rep object option in converter settings. The converted B-rep object is either an item or a concrete item and is added to the shape catalog.
Skip to main content. The file construsoft. Environment settings The file construsoft. TRUE: P2. Text settings The file construsoft. You can for example define the outer contour, the inner contour and texts. Was this helpful? What is missing? Leave this field blank. File dstv2dxf. Use to add the input file extension to the output file.
Draw crosshair for holes and slotted holes. The part face can only be created from one side. C12X30 C12X C15X40 C15X C15X50 C15X Below there is first an example of an incorrect conversion file and then of a correct one, errors are highlighted:. Skip to main content. Create conversion files Tekla Structures.
Create conversion files You can create your own conversion files if the ones that come with Tekla Structures installation do not suit your needs. Open an existing conversion file using any standard text editor. Save the file with another name. Modify the file: enter profile names recognized by Tekla Structures in the first column, and the corresponding name recognized by the other software in the second column.
0コメント